23032501

23032501 - Huber Suhner(HUBER+SUHNER)
Увеличить
Краткое описание: Coaxial hybrid surge protector, 15 V DC, 3 A, N-jack

Дополнительная информация

Coaxial surge protector device uses two-stage hybrid protection with a replaceable gas discharge tube and fine protector circuitry. The 50 ohm RF path operates over an 800 MHz to 2000 MHz frequency frame and supports 15 V DC supply voltage with 3 A DC current for remote powering. N jack female ports provide unprotected and protected connections in a box-design housing with aluminium chromatized construction. The mated device is rated IP66 and operates from -40 °C to 85 °C, with RoHS compliance by exemption and REACH SVHC lead content declared.
Weight 352g
Gas tube Yes DC, GDT included, replaceable, 9071.99.0548 (90 V)
Impedance 50Ω
DC current 3A
Rohs Rating Compliant with exemption 6c
Product code 3403.17.0045
Reach Rating Contains one or more SVHC >0.1%
Mating cycles 500
Reach Details CAS: 7439-92-1 Lead
CW power frame 50W
Rohs Directive RoHS 2011/65/EU and (EU) 2015/863
Frequency frame 800 to 2000MHz
Frequency range 1500 to 1600MHz
Reach Regulation REACH 1907/2006 Article 33 SVHC
DC supply voltage 15V
Ingress protection Mated / IP66, according to IEC 60529
Product description Fine protector hybrid technology
Return loss typical 20dB
Storage temperature -40 to 85°C
Main path connectors Port 1: unprotected N jack female; Port 2: protected N jack female
Operating temperature -40 to 85°C
Insertion loss typical 0.4dB
Mounting and grounding MH119 bulkhead mounting, M4 screw, bracket
Housing material and plating Aluminium / Chromatized
Residual pulse energy typical 3, test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µsµJ
Residual pulse voltage typical 18 LEMP, test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µsV
Surge current handling capability 25 single, 10 multiple, test pulse 8/20 µskA