This phenolic thermostat features a fixed set point with open on rise function and manual reset. It has a minimum insulation resistance of 500 and maximum contact resistance of 50. The thermostat is rated for operation between 0 and 150°C and can withstand up to 250V AC and 15A. The open temperature is 76.7°C with a tolerance of 4.4°C.
| RoHS Version |
2002/95/EC |
| Set Point Type |
Fixed |
| Contact Material |
Silver/Nickel Alloy |
| Manufacturer Type |
Phenolic Thermostat |
| Max Current Rating |
15A |
| Set Point Function |
Open on Rise |
| Reset Configuration |
Manual |
| Switch Configuration |
N.C. |
| Max AC Voltage Rating |
250V |
| Open Tolerance (Celsius) |
4.4°C |
| Max Operating Temperature |
150°C |
| Min Operating Temperature |
0°C |
| Maximum Contact Resistance |
50mOhm |
| Open Temperature (Celsius) |
76.7°C |
| Open Tolerance (Fahrenheit) |
8°F |
| Minimum Insulation Resistance |
500MOhm |
| Open Temperature (Fahrenheit) |
170°F |