Краткое описание: MAGNETRON 2M248 Series
Производитель Toshiba
Категория Волноводы

Дополнительная информация

Toshiba 2M248 series is a fixed frequency continuous wave magnetron intended for use in microwave cooking appliances. The average output power is 1030 watts to a matched load at 330 mA anode current in the frequency range from 2450 to 2470 MHz. The tube is a packaged magnet type and requires forced air cooling. The output is fed either into a rectangular waveguide or into an oven cavity directly.
Cooling Forced air (Side blow)
Regulatory Complies with tighter regulations on spurious radiation and line conducted noise
Magnetic Field Ferrite magnet packaged
Anode Potential to be ground
Output Coupling See outline drawing
Type of Cathode Directly heated thoriated tungsten filament
Filament Current 10.0A
Weight (approx.) 830g
Mounting Position Any
Filament Potential Negative high voltage
Physical Dimensions See outline drawing
Terminal Connection See outline drawing
Cold Filament Resistance 0.03ohms
Frequency (matched load) 2460 ± 10MHz
Filament Voltage (Nominal) 3.15V
Typical Operation - Frequency 2460MHz
Typical Operation - Output Power 1030W
Typical Operation - Power Supply Single phase full wave rectified without filter
Filament Transformer Design Center 3.15 ±0.1V
Absolute Maximum Rating - Load VSWR 4
Typical Operation - Cooling Air Flow 800ℓ/min
Typical Operation - Filament Voltage 3.15V
Typical Operation - Peak Anode Voltage 4.35kV
Typical Operation - Average Anode Current 330mAdc
Absolute Maximum Rating - Case Temperature 120°C
Absolute Maximum Rating - Anode Input Power 1.8kW
Absolute Maximum Rating - Anode Temperature 300°C
Typical Operation - Pressure Drop (Approx.) 70Pa
Absolute Maximum Rating - Peak Anode Current 1.5A
Absolute Maximum Rating - Peak Anode Voltage 4.85kV
Maximum Anode Temperature (Normal Condition) 250°C
Absolute Maximum Rating - Average Anode Current 380mAdc
Absolute Maximum Rating - Filament Voltage (Max) 3.6V
Absolute Maximum Rating - Filament Voltage (Min) 2.7V
Absolute Maximum Rating - Cathode Preheating Time 0s
Standard Ambient Temperature (during measurement) 25°C
Absolute Maximum Rating - Antenna Seal Temperature 320°C
Absolute Maximum Rating - Storage Temperature (Max) 60°C
Absolute Maximum Rating - Storage Temperature (Min) -30°C