400-0001-01

400-0001-01 - Nextek(NexTek)
Увеличить
Краткое описание: 90 V replacement gas discharge tube surge protector

Дополнительная информация

Replacement gas discharge tube provides surge protection for NexTek lightning arrestor assemblies. The device uses an 8 mm diameter by 6 mm long ceramic-insulated GDT format and is intended for high transient current capability with RF surge protection applications. The 90 V protection-voltage version has voltage code 09 and a 3 W RF power rating. Let-through performance is specified as 600 Vpk and 0.3 mJ for a 6 kV, 1.2 x 50 μs and 3 kA, 8 x 20 μs input surge.
RF power 3W
Application Replacement GDT for NexTek lightning arrestor
Body length 6mm
Product type Gas discharge tube
Voltage code 09
Body diameter 8mm
Maximum frequency 0MHz
Minimum frequency 0MHz
Insulator material Ceramic
Let-through energy 0.3mJ
Protection voltage 90V
Pulse current life 10 pulses of 20 kA, 8 μs x 20 μs
Let-through voltage 600Vpk
Surge input current waveform 3 kA @ 8 x 20 μs
Surge input voltage waveform 6 kV @ 1.2 x 50 μs