6ES7135-6FB00-0BA1

6ES7135-6FB00-0BA1 - Siemens
Увеличить
Краткое описание: SIMATIC ET 200SP, Analog output module, AQ 2xU Standard
Производитель Siemens
Категория Контроллеры

Дополнительная информация

Analog output module, 2 channels, universal use. Pack quantity: 1 unit, suitable for BU type A0, A1 BaseUnits, Color code CC00, Module diagnostics, 16 bit resolution.
MSO No
Depth 58 mm
Width 15 mm
Height 73 mm
I&M data Yes; I&M0 to I&M3
Oversampling No
Last modified 8/7/2023
Weight, approx. 31 g
Diagnostic alarm Yes
Isochronous mode No
Power loss, typ. 1 W
Rated value (DC) 24 V
Usable BaseUnits BU type A0, A1
FW update possible Yes
Diagnostics function Yes
HW functional status From FS03
Isolation tested with 707 V DCtype test
Output range scalable No
Diagnoses, Group error Yes
Output range, 0 to 10 V Yes; 15 bit
Diagnoses, Short-circuit Yes
Number of analog outputs 2
Output range, 1 V to 5 V Yes; 13 bit
Product type designation AQ 2xU ST
Current consumption, max. 80 mA
Mechanical coding element Yes
Output range, -5 V to +5 V Yes; 15 bit incl. sign
Calibration possible in RUN No
Reverse polarity protection Yes
Cable length, shielded, max. 200 m
Output range, -10 V to +10 V Yes; 16 bit incl. sign
Diagnoses, Overflow/underflow Yes
Substitute values connectable Yes
Address space per module, max. 4 byte; + 1 byte for QI information
Analog output with oversampling No
Cycle time (all channels), min. 1 ms
Settling time, for resistive load 0.1 ms
Type of mechanical coding element Type A
Reparameterization possible in RUN Yes
Settling time, for capacitive load 1 ms
Crosstalk between the outputs, min. -50 dB
Permissible range, lower limit (DC) 19.2 V
Permissible range, upper limit (DC) 28.8 V
PROFIBUS from GSD version/GSD revision GSD Revision 5
PROFINET from GSD version/GSD revision GSDML V2.3
Diagnoses, Monitoring the supply voltage Yes
Load impedance with voltage outputs, min. 2 kΩ
Linearity error (relative to output range) +/- 0.03%
Potential separation, between the channels No
Installation altitude above sea level, max. 5000 mRestrictions for installation altitudes > 2000 m, see manual
STEP 7 configurable/integrated from version V5.5 SP3/-
Voltage output, short-circuit current, max. 45 mA
Temperature error (relative to output range) +/- 0.005%/K
Diagnostics indication LED, Channel status display Yes; green LED
Diagnostics indication LED, for module diagnostics Yes; green/red DIAG LED
Diagnostics indication LED, for channel diagnostics No
Basic error limit, Current, relative to output range +/- 0.3%
Basic error limit, Voltage, relative to output range +/- 0.3%
Resolution with overrange (bit including sign), max. 16 bit
STEP 7 TIA Portal configurable/integrated from version V13 SP1/-
Color code for module-specific color identification plate CC00
Load impedance with voltage outputs, capacitive load, max. 1 µF
Operational error limit, Current, relative to output range +/- 0.5%
Operational error limit, Voltage, relative to output range +/- 0.5%
Potential separation, between the channels and backplane bus Yes
Connection of actuators, for voltage output two-wire connection Yes
Connection of actuators, for voltage output four-wire connection No
Ambient temperature during operation, vertical installation, max. 50 °C
Ambient temperature during operation, vertical installation, min. -30 °C; < 0 °C as of FS03
Ambient temperature during operation, horizontal installation, max. 60 °C
Ambient temperature during operation, horizontal installation, min. -30 °C; < 0 °C as of FS03
Repeat accuracy in steady state at 25 °C (relative to output range) +/- 0.05%
Diagnostics indication LED, Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
Potential separation, between the channels and the power supply of the electronics Yes
Destruction limits against externally applied voltages and currents, Voltages at the outputs 30 V