84014636

84014636 - Huber Suhner
Увеличить
Краткое описание: 50 Ω GDT Coaxial Surge Protector, 1 GHz

Дополнительная информация

The coaxial surge protector uses gas-discharge-tube technology for DC to 1 GHz RF lines and supports 50 Ω systems. It provides N jack female connectors on the protected and unprotected ports with MH12 bulkhead mounting. The device handles 30 kA single and 20 kA multiple surge currents for an 8/20 µs pulse and supports up to 150 W CW power. It operates from -40 °C to 85 °C with IP65 ingress protection and includes a replaceable SEMPER 230 V gas tube. RoHS compliance is declared with exemption 6c, and REACH declaration indicates lead above 0.1%.
Weight 114g
CW power ≤ 150W
Gas tube Yes DC, GDT included, replaceable, 9071.99.0647 (SEMPER, 230 V)
Impedance 50Ω
DC current 2.5A
Technology GDT technology up to 1.0 GHz
Rohs Rating Compliant with exemption
Product code 3401.17.0048-EX
Reach Rating Contains one or more SVHC >0.1%
Mating cycles 500
Reach Details CAS: 7439-92-1 Lead
Recovery time 7 sec. at 25°C ambient temperature
Turn-off time 20 sec. typically at 2.0 A and 25°C ambient temperature
Rohs Directive RoHS 2011/65/EU and (EU) 2015/863
Rohs Exemption 6c
Frequency range 0 MHz to 1000 MHz
Reach Regulation REACH 1907/2006 Article 33 SVHC
DC supply voltage 48V
Return loss typical ≥ 24dB
Storage temperature -40 to 85°C
Main path connectors Port 1: unprotected, N jack (female); Port 2: protected, N jack (female)
Operating temperature -40 to 85°C
Insertion loss typical ≤ 0.1dB
Mounting and grounding MH12 (bulkhead mounting)
Ingress protection rating IP65
Housing material / plating Brass / SUCOPLATE (R) Plating
Residual pulse energy typical 350 µJ (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs)
Residual pulse voltage typical 650 V (test pulse 4 kV 1.2/50 µs; 2 kA 8/20 µs)
Surge current handling capability 30 kA single, 20 kA multiple (test pulse 8/20 µs)