The differential pressure sensor operates within a pressure range of -20kPa to 20kPa and can withstand a maximum overload pressure of 40kPa. It requires a supply voltage between 3 and 3.6 volts and consumes a maximum supply current of 5mA. The device maintains an accuracy of ±2 and features a response time of 0.46 seconds. The operating temperature range spans from -20 to 105°C.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±2% |
| Pin Count |
8 |
| Package/Case |
DIP |
| RoHS Version |
2002/95/EC |
| Response Time |
0.46ms |
| Package Family Name |
DIP |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
5mA |
| Operating Pressure Range |
-20kPa to 20kPa |
| Max Operating Temperature |
105°C |
| Maximum Overload Pressure |
40kPa |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |