DT-M200-120-V-TN
Дополнительная информация
| MTBF | 300000 at 25 °Chours |
| RoHS | Yes |
| Ripple | 1 max at full load% Vp-p |
| Weight | 900g |
| Cooling | Natural convection |
| Topology | LLC |
| Efficiency | Energy Star Level VI, ErP Stage 2 certified |
| Hold-up Time | 10 at full loadms |
| Output Power | 192W |
| RoHS Version | 2011/65/EU |
| Input Current | 2.5-0.9A |
| Input Voltage | 100-240VAC |
| Line Frequency | 50-60Hz |
| Output Current | 16A |
| Output Voltage | 12VDC |
| Case Dimensions | 204 x 81 x 42.5mm |
| Leakage Current | <100µA |
| Load Regulation | ±5 typical% |
| Input Plug Option | IEC60320 C14 |
| Transient Response | 0.5 typical for 50% load changems |
| Storage Temperature | -20 to 80°C |
| Dielectric Withstand | 4000 primary-secondaryVAC |
| Operating Temperature | 0 to +40°C |
| Over Current Protection | 120-150 max% of Iout |
| Over Voltage Protection | 120-150 max% of Vout |
| Operating Relative Humidity | 20 to 80% RH |
Если у вас не открывается документ, нажмите, чтобы открыть файл в новой вкладке.