The EC010BG6PC is a gage pressure sensor with an operating range of 0 to 10bar and a maximum overload pressure of 20bar. It has an accuracy of ±0.25 and operates over a temperature range of -40 to 105 degrees Celsius. The device is supplied with a typical voltage of 5V and a maximum current of 17mA. It has a response time of 0.5 seconds and is available with a 3-pin package with Packard termination. The sensor is rated for IP66 and is suitable for industrial applications.
| Accuracy |
±0.25% |
| IP Rating |
IP66 |
| Pin Count |
3 |
| Port Size |
G1/4-19 BSP |
| RoHS Version |
2002/95/EC |
| Response Time |
0.5ms |
| Output Voltage |
0.5 to 4.5V |
| Device Pressure Type |
Gage |
| Electrical Termination |
Packard |
| Maximum Supply Current |
17mA |
| Operating Pressure Range |
0bar to 10bar |
| Max Operating Temperature |
105°C |
| Maximum Overload Pressure |
20bar |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
7V |
| Typical Operating Supply Voltage |
5V |