The HSCDDRN160MDSA3 is a differential pressure sensor from Honeywell, operating within a pressure range of -0.16bar to 0.16bar. It can withstand a maximum overload pressure of 1.4bar and has an accuracy of ±0.25. The sensor's operating temperature range is between -20°C and 85°C, and it requires a supply voltage between 3V and 3.6V, with a typical operating voltage of 3.3V. The maximum supply current is 3.9mA, and the response time is 0.46ms.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
3.9mA |
| Operating Pressure Range |
-0.16bar to 0.16bar |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
1.4bar |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |