The HSCDLNN006BG5A3 is a gage pressure sensor from Honeywell, designed to measure pressures up to 6bar with an accuracy of ±0.25%. It operates within a temperature range of -20°C to 85°C and requires a supply voltage of 3.3V. The device has a maximum supply current of 3.9mA and features a response time of 0.46ms. It is suitable for use in air and gas media and is available in an 8-pin DIP module package.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Gage |
| Maximum Supply Current |
3.9mA |
| Operating Pressure Range |
0bar to 6bar |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
17bar |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |