This differential pressure sensor from Honeywell features an operating pressure range of -30psi to 30psi and a maximum overload pressure of 60psi. It operates within a temperature range of -20°C to 85°C and has an accuracy of ±0.25. The device requires a supply voltage of 3.6V or less and draws a maximum supply current of 2.1mA. It is suitable for use in air or gas media and has a response time of 0.46 seconds.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2002/95/EC |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
2.1mA |
| Operating Pressure Range |
-30psi to 30psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
60psi |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |