The HSCDLNN100MD2A3 differential pressure sensor from Honeywell operates over a pressure range of -0.1bar to 0.1bar and can withstand up to 0.5bar overload pressure. It has a maximum supply voltage of 3.6V and a typical operating supply voltage of 3.3V, with a maximum supply current of 2.1mA. The sensor has an accuracy of ±0.25 and a response time of 0.46. It is designed for use in air or gas media and has a DIP module package.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2002/95/EC |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
2.1mA |
| Operating Pressure Range |
-0.1bar to 0.1bar |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
0.5bar |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |