The HSCDLNN400MDAA5 is a differential pressure sensor from Honeywell with a maximum operating supply voltage of 5.25V and a maximum supply current of 3A. It operates over a pressure range of -0.4bar to 0.4bar and can withstand a maximum overload pressure of 1.4bar. The device has an accuracy of ±0.25 and a response time of 1ms. It is available in an 8-pin DIP module package and is suitable for use in air or gas media.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2002/95/EC |
| Response Time |
1ms |
| Output Voltage |
0.5 to 4.5V |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
3mA |
| Operating Pressure Range |
-0.4bar to 0.4bar |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
1.4bar |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
5.25V |
| Min Operating Supply Voltage |
4.75V |
| Typical Operating Supply Voltage |
5V |