The differential pressure sensor operates over a range of -1psi to 1psi with an accuracy of ±0.25%. It can withstand a maximum overload pressure of 10psi and has a response time of 0.46 seconds. The device requires a supply voltage between 4.75V and 5.25V, with a typical operating voltage of 5V. It is suitable for use in air or gas media and is available in a DIP-8 package.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
4.6mA |
| Operating Pressure Range |
-1psi to 1psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
10psi |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
5.25V |
| Min Operating Supply Voltage |
4.75V |
| Typical Operating Supply Voltage |
5V |