The HSCDLNV001PDSA3 differential pressure sensor from Honeywell operates over a pressure range of -1psi to 1psi and can withstand up to 10psi overload pressure. It has a maximum supply current of 3.9mA and a typical operating supply voltage of 3.3V. The device is accurate to ±0.25% and has a response time of 0.46 seconds. It is designed for use in air or gas media and is suitable for board mount applications.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
3.9mA |
| Operating Pressure Range |
-1psi to 1psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
10psi |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |