The HSCDRNN005PDSA3 is a differential pressure sensor from Honeywell, designed for board mount applications. It operates within a pressure range of -5psi to 5psi and can withstand a maximum overload pressure of 30psi. The device requires a supply voltage between 3V and 3.6V, with a typical operating voltage of 3.3V and a maximum supply current of 3.9mA. The sensor's accuracy is ±0.25% and it features a response time of 0.46 seconds. It is suitable for use in air and gas media, and is suitable for use in temperatures ranging from -20°C to 85°C.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
3.9mA |
| Operating Pressure Range |
-5psi to 5psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
30psi |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |