The HSCDRNN060PDSA3 is a differential pressure sensor from Honeywell, operating within a pressure range of -60psi to 60psi. It can withstand a maximum overload pressure of 250psi. The device requires a supply voltage between 3 and 3.6 volts, with a typical operating voltage of 3.3 volts. The maximum supply current is 3.9mA. The sensor has a response time of 0.46 seconds and is designed for use in air or gas media. It is a board-mount device with an 8-pin DIP module package, suitable for use in temperatures ranging from -20 to 85 degrees Celsius.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
3.9mA |
| Operating Pressure Range |
-60psi to 60psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
250psi |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |