The HSCDRNT100MD4A3 is a differential pressure sensor from Honeywell, designed for use in environmental sensing applications. It features an operating pressure range of -0.1bar to 0.1bar and can withstand maximum overload pressures of up to 1.4bar. The device operates within a temperature range of -20°C to 85°C and requires a supply voltage of up to 3.6V, with a typical operating voltage of 3.3V. The HSCDRNT100MD4A3 has an accuracy of ±0.25 and a response time of 0.46 seconds, making it suitable for a range of applications including air and gas sensing.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
3.9mA |
| Operating Pressure Range |
-0.1bar to 0.1bar |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
1.4bar |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |