The HSCDRNV015PD6A3 differential pressure sensor from Honeywell operates over a pressure range of -15psi to 15psi and can withstand a maximum overload pressure of 60psi. It has an accuracy of ±0.25 and a response time of 0.46. The device is powered by a supply voltage of 3.3V, with a typical operating voltage of 3.3V and a maximum supply current of 3.9mA. The sensor is designed for use in air and gas media and has a temperature range of -20°C to 85°C.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
3.9mA |
| Operating Pressure Range |
-15psi to 15psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
60psi |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |