The HSCMLNN060PDAA3 is a differential pressure sensor from Honeywell, designed for environmental sensing applications. It operates within a pressure range of -60psi to 60psi and can withstand maximum overload pressures of 120psi. The device requires a supply voltage between 3 and 3.6 volts, with a typical operating voltage of 3.3 volts and a maximum supply current of 2.1 milliamps. The sensor's output voltage ranges from 0.33 to 2.97 volts, with an accuracy of ±0.25 and a response time of 1 millisecond. It is suitable for use in air or gas environments and is available in an 8-pin SMD module package.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
SMD Module |
| RoHS Version |
2002/95/EC |
| Response Time |
1ms |
| Output Voltage |
0.33 to 2.97V |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
2.1mA |
| Operating Pressure Range |
-60psi to 60psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
120psi |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |