The HSCMLNT030PD3A3 is a differential pressure sensor from Honeywell, operating over a range of -30psi to 30psi with an accuracy of ±0.25%. It can withstand a maximum overload pressure of 120psi and has a response time of 0.46 seconds. The device is powered by a supply voltage between 3 and 3.6 volts, with a typical operating voltage of 3.3 volts and a maximum supply current of 3.9 milliamps. The HSCMLNT030PD3A3 is a surface-mount device (SMD) with an 8-pin package and is suitable for use in board mount applications.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
SMD Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
3.9mA |
| Operating Pressure Range |
-30psi to 30psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
120psi |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |