The differential pressure sensor operates over a range of -10inH2O to 10inH2O with an accuracy of ±0.25. It can withstand maximum overload pressures of 350inH2O and has a response time of 0.46. The device is powered by a supply voltage between 3.27 and 3.33V, with a typical operating voltage of 3.3V and a maximum supply current of 3.9mA. The sensor is designed for use in air and gas media and has a minimum operating temperature of -20°C and a maximum operating temperature of 85°C.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
SMD Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
3.9mA |
| Operating Pressure Range |
-10inH2O to 10inH2O |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
350inH2O |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
3.33V |
| Min Operating Supply Voltage |
3.27V |
| Typical Operating Supply Voltage |
3.3V |