The HSCSAAD002ND2A5 differential pressure sensor from Honeywell offers a ±0.25% accuracy over an operating pressure range of -2inH2O to 2inH2O. It can withstand a maximum overload pressure of 270inH2O and operates within a temperature range of -20°C to 85°C. The device requires a supply voltage between 4.95V and 5.05V, with a typical operating voltage of 5V and a maximum supply current of 4.6mA. The sensor is designed for air and gas media and features a response time of 0.46ms.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
4 |
| Package/Case |
SIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
4.6mA |
| Operating Pressure Range |
-2inH2O to 2inH2O |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
270inH2O |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
5.05V |
| Min Operating Supply Voltage |
4.95V |
| Typical Operating Supply Voltage |
5V |