The HSCSAND015PG2A5 is a gage pressure sensor with an operating range of 0 to 15psi and a maximum overload pressure of 30psi. It operates at a maximum supply voltage of 5.25V and has an accuracy of ±0.25. The device is suitable for use in air or gas media and has a response time of 0.46. The HSCSAND015PG2A5 is a 4-pin SIP module that can operate within a temperature range of -20 to 85 degrees Celsius.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
4 |
| Package/Case |
SIP Module |
| RoHS Version |
2002/95/EC |
| Response Time |
0.46ms |
| Device Pressure Type |
Gage |
| Maximum Supply Current |
3mA |
| Operating Pressure Range |
0psi to 15psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
30psi |
| Min Operating Temperature |
-20°C |
| Max Operating Supply Voltage |
5.25V |
| Min Operating Supply Voltage |
4.75V |
| Typical Operating Supply Voltage |
5V |