The IALH11-1-52-5.00-A-01 is a hydraulic magnetic circuit breaker with a screw terminal design and panel mount configuration. It features a 2-pole design with a voltage rating of 125VDC and a current rating of 5A. The breaker has a trip time range of 1-10 seconds and is actuated by a handle. It operates within a temperature range of -40°C to 85°C.
| ECCN |
EAR99 |
| PPAP |
No |
| Type |
Hydraulic Magnetic |
| EU RoHS |
Yes |
| HTS Code |
8536200040 |
| Mounting |
Panel Mount |
| Cage Code |
82647 |
| Trip Time |
1s to 10s |
| Automotive |
No |
| Schedule B |
8536300000 |
| AEC Qualified |
No |
| Actuator Type |
Handle |
| RoHS Versions |
2011/65/EU, 2015/863 |
| Current Rating |
5A |
| Voltage Rating |
125VDC |
| Number of Poles |
2 |
| Terminal Design |
Screw |
| Number of Terminals |
4 |
| Max Operating Temperature |
85°C |
| Min Operating Temperature |
-40°C |