This hydraulic magnetic circuit breaker is rated for 80VDC and 35A with a maximum trip time of 0.05 seconds. It features a toggle actuator and is designed for panel mount applications. The operating temperature range is -40 to 85 degrees Celsius. The terminals are screw designed for secure connections.
| RoHS |
Yes with Exemption |
| Type |
Hydraulic Magnetic |
| Mounting |
Panel Mount |
| Trip Time |
0.05s(Max) |
| RoHS Version |
2011/65/EU, 2015/863 |
| Actuator Type |
Toggle |
| Current Rating |
35A |
| Voltage Rating |
80VDC |
| Number of Poles |
1 |
| Terminal Design |
Screw |
| Number of Terminals |
2 |
| Max Operating Temperature |
85°C |
| Min Operating Temperature |
-40°C |