This hydraulic magnetic relay features a screw terminal design and a panel mount configuration. It has five terminals and a single pole configuration. The device is rated for 80VDC and can handle up to 30A of current. The actuator type is a handle, and the trip time ranges from 0.1s to 1.2s. The relay operates within a temperature range of -40°C to 85°C.
| ECCN |
EAR99 |
| PPAP |
No |
| Type |
Hydraulic Magnetic |
| EU RoHS |
Yes with Exemption |
| HTS Code |
8536200040 |
| Mounting |
Panel Mount |
| Cage Code |
82647 |
| Trip Time |
0.1s to 1.2s |
| Automotive |
No |
| Schedule B |
8536300000 |
| AEC Qualified |
No |
| Actuator Type |
Handle |
| RoHS Versions |
2011/65/EU, 2015/863 |
| Current Rating |
30A |
| Voltage Rating |
80VDC |
| Number of Poles |
1 |
| Terminal Design |
Screw |
| Number of Terminals |
5 |
| Max Operating Temperature |
85°C |
| Min Operating Temperature |
-40°C |