This gage pressure sensor operates within a pressure range of 0 to 100psi and features an accuracy of ±0.5%. It has a 3-pin configuration and provides an output voltage of 0.5 to 4.5V. The sensor's operating temperature range is -40 to 105°C, and it can withstand a maximum overload pressure of 300psi. The device is designed for use in industrial environments and is suitable for both gas and liquid media.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±0.5% |
| Pin Count |
3 |
| Port Size |
7/16-20 UNF |
| RoHS Version |
2011/65/EU |
| Response Time |
1ms |
| Output Voltage |
0.5 to 4.5V |
| Device Pressure Type |
Gage |
| Electrical Termination |
Packard |
| Maximum Output Current |
0.45mA |
| Maximum Supply Current |
6mA |
| Operating Pressure Range |
0psi to 100psi |
| Max Operating Temperature |
105°C |
| Maximum Overload Pressure |
300psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
5.5V |
| Min Operating Supply Voltage |
4.5V |
| Typical Operating Supply Voltage |
5V |