The P51-2000A-Z-I12-4.5V is an absolute pressure transducer with an operating pressure range of 0 to 2000psi and a maximum overload pressure of 20000psi. It has a minimum operating temperature of -40 degrees Celsius and a maximum operating temperature of 105 degrees Celsius. The device is designed for use with a 1/4-18 NPT port and has a typical operating supply voltage of 5 volts. It is suitable for use with both gas and liquid media and has a response time of 1 second. The transducer has a maximum output current of 0.45 amps and a maximum supply current of 6 amps.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±1% |
| Pin Count |
3 |
| Port Size |
1/4-18 NPT |
| RoHS Version |
2011/65/EU |
| Response Time |
1ms |
| Output Voltage |
0.5 to 4.5V |
| Device Pressure Type |
Absolute |
| Electrical Termination |
Integral Harness |
| Maximum Output Current |
0.45mA |
| Maximum Supply Current |
6mA |
| Operating Pressure Range |
0psi to 2000psi |
| Max Operating Temperature |
105°C |
| Maximum Overload Pressure |
20000psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
5.5V |
| Min Operating Supply Voltage |
4.5V |
| Typical Operating Supply Voltage |
5V |