This gage pressure sensor operates within a pressure range of 0 to 200psi and has a maximum overload pressure of 600psi. It features an accuracy of ±0.5 and a response time of 1. The device is designed to operate within a temperature range of -40 to 105 degrees Celsius. The sensor is available with typical operating supply voltages of 9, 12, 15, 18, or 24 volts and is suitable for use with both gas and liquid media.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±0.5% |
| Pin Count |
4 |
| Port Size |
9/16-18 UNF |
| RoHS Version |
2011/65/EU |
| Response Time |
1ms |
| Device Pressure Type |
Gage |
| Electrical Termination |
Connector |
| Operating Pressure Range |
0psi to 200psi |
| Max Operating Temperature |
105°C |
| Maximum Overload Pressure |
600psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
30V |
| Min Operating Supply Voltage |
8V |
| Typical Operating Supply Voltage |
9|12|15|18|24V |