The pressure sensor operates within a sealed gage pressure range of 0 to 500psi with an accuracy of ±0.5%. It can withstand a maximum overload pressure of 1500psi. The device is designed to function within a temperature range of -40 to 105 degrees Celsius. It can be supplied with a voltage between 4.5 and 5.5 volts, with a typical operating voltage of 5 volts. The maximum supply current is 6 milliamps. The sensor has a 1.2-20 UNF-2A port size and is electrically terminated with an integral harness. It can operate with both gas and liquid media and has a response time of 1 millisecond. The output voltage ranges from 0.5 to 4.5 volts, with a maximum output current of 0.45 amps.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±0.5% |
| Pin Count |
3 |
| Port Size |
1.2-20 UNF-2A |
| RoHS Version |
2011/65/EU |
| Response Time |
1ms |
| Output Voltage |
0.5 to 4.5V |
| Device Pressure Type |
Sealed Gage |
| Electrical Termination |
Integral Harness |
| Maximum Output Current |
0.45mA |
| Maximum Supply Current |
6mA |
| Operating Pressure Range |
0psi to 500psi |
| Max Operating Temperature |
105°C |
| Maximum Overload Pressure |
1500psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
5.5V |
| Min Operating Supply Voltage |
4.5V |
| Typical Operating Supply Voltage |
5V |