The P51-50G-H-P-4.5V pressure transducer operates within a pressure range of 0 to 50psi and is a gage device. It can withstand a maximum overload pressure of 150psi. The device has an accuracy of ±1 and an operating temperature range of -40 to 105°C. It is powered by a supply voltage between 4.5 and 5.5V, with a typical operating voltage of 5V and a maximum supply current of 6mA. The transducer has a response time of 1 and an output voltage range of 0.5 to 4.5V.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±1% |
| Pin Count |
3 |
| Port Size |
M12-1.5 6g |
| RoHS Version |
2011/65/EU |
| Response Time |
1ms |
| Output Voltage |
0.5 to 4.5V |
| Device Pressure Type |
Gage |
| Electrical Termination |
Packard |
| Maximum Output Current |
0.45mA |
| Maximum Supply Current |
6mA |
| Operating Pressure Range |
0psi to 50psi |
| Max Operating Temperature |
105°C |
| Maximum Overload Pressure |
150psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
5.5V |
| Min Operating Supply Voltage |
4.5V |
| Typical Operating Supply Voltage |
5V |