PCA-BA-20-210-1BC-AAA

PCA-BA-20-210-1BC-AAA - Carling Technologies
Краткое описание: AC Residual Current Circuit Breaker with Overcurrent Protection

Дополнительная информация

AC residual-current circuit breaker with overcurrent protection combines ground-fault protection with hydraulic-magnetic circuit breaker tripping. The PC-Series supports one- to three-pole configurations with 120 VAC and 120/240 VAC ratings and up to 5,000 A maximum interrupting capacity. The ordering code indicates a 120 VAC single-phase, one-pole series-trip configuration with handle actuation and an instantaneous 50/60 Hz delay curve. The family is designed for -35 °C to +66 °C operation and includes integrated LED status indication and a manual test function.
RoHS Yes
Phase Single-phase
Series PC-Series
Mounting Front panel, #6-32 or M3 threaded inserts
Endurance 10000 on-offoperations
Product Type Equipment Leakage Circuit Interrupter
RoHS Version 2002/95/EC
Actuator Type Handle
Current Rating 0.10A
System Voltage 120VAC
Number of Poles 1
Dielectric Strength 1480 for 1 minute at 60 HzVAC
Frequency and Delay 50/60 Hz instantaneous
Operating Frequency 50/60Hz
Circuit Configuration Series trip current
Insulation Resistance 100 minimum at 500 VDCMΩ
Operating Temperature -35 to +66°C
Leakage Current Trip Time ≤25ms
Maximum Interrupting Capacity 5000A
Maximum Series Current Rating 50A