PTCONFONF09E

PTCONFONF09E - Nextek(NexTek)
Увеличить
Краткое описание: N-Type Female Fixed Gas Discharge Tube RF Surge Protector

Дополнительная информация

Fixed gas discharge tube lightning arrestor provides bidirectional RF surge protection for broadband wireless, Wi-Fi, telecom, and 4G/5G applications. The unit uses N-Type female input and output connectors with normal polarity and a 50 ohm RF path from DC to 6 GHz. It handles up to 30 W RF input power, 10 A through current, and a 20 kA 8/20 µs maximum transient surge. Bulkhead mounting and rugged waterproof construction support harsh RF installation environments.
VSWR 1.30 typical, 1.45 maximum
Impedance 50ohm
DC Handling DC Pass
Insertion Loss 0.25 typical, 0.35 maximumdB
Mounting Style Bulkhead
Frequency Range DC to 6GHz
Turn-On Voltage 90 ±20%V
Connector Polarity Normal
Connector-In Gender Female
Connector-In Series N-Type
Maximum Input Power 30W
Connector-Out Gender Female
Connector-Out Series N-Type
Surge Protector Type LEMP
Maximum Transient Surge 20, 8/20 µskA
Directionality Operation Bi-Directional
Maximum Operating Current 10A
Maximum Operating Voltage 60V
Surge Protector Technology GDT, Gas Discharge Tube
Operating Temperature Range -40 to +90°C