PTCTNMTNF09S

PTCTNMTNF09S - Nextek(SurgeGuard)
Увеличить
Краткое описание: 90 V TNC male-to-female gas discharge surge arrestor

Дополнительная информация

Gas discharge tube lightning arrestor provides bidirectional RF surge protection with TNC male-to-TNC female connectors. The 50 ohm device passes DC and is specified for operation through 2.5 GHz with 1.25 maximum VSWR to 2.0 GHz and 1.60 maximum VSWR from 2.0 to 2.5 GHz. The 90 V protection-voltage version supports 37 W RF power and has 600 V peak let-through at 0.3 microjoule. It is rated for 40 kA maximum 8x20 microsecond transient current and multiple strikes of 20 kA for about 10 events. The male-to-female style uses an integral ground lug, has IP65 dust and splash resistance, and operates from -40 °C to +90 °C.
Weight 0.12 lb typ / 55 g typ
Connector 1 TNC male
Connector 2 TNC female
Product type Gas discharge tube lightning arrestor
Voltage code 09
Frequency range DC to 2.5GHz
Gasket material Elastomer
Nominal impedance 50ohm
Insulator material PTFE
Protection voltage 90V
VSWR, DC to 2.0 GHz 1.25 max
VSWR, 2.0 to 2.5 GHz 1.60 max
Standard model suffix S
Mounting and grounding Male-to-female style with integral ground lug
Maximum transient current 40, 8x20 µskA
Dust and waterproof rating IEC 529 IP65
Multiple strike capability 20, about 10 timeskA
Operating temperature range -40 to +90°C
Insertion loss, DC to 2.0 GHz 0.15 maxdB
Insertion loss, 2.0 to 2.5 GHz 0.40 maxdB
Outer parts material and finish Brass, nickel finish
Center contact material and finish BeCu, gold finish
RF power at 90 V protection voltage 37W
Let-through at 90 V protection voltage 600 Vpk / 0.3 µJ

Если у вас не открывается документ, нажмите, чтобы открыть файл в новой вкладке.