PTRONMONF99S

PTRONMONF99S - Nextek
Увеличить
Краткое описание: N-Male to N-Female Replaceable GDT RF Surge Arrestor
Производитель Nextek

Дополнительная информация

Replaceable gas discharge tube RF lightning arrestor provides bidirectional surge protection for coaxial N-connector lines. The N-male to N-female design operates from dc to 3.2 GHz with 50 ohm nominal impedance and low insertion loss. It supports 50 kA maximum transient surge protection, 20 kA multiple strikes for 10 events, and a 1000 V replaceable gas tube for the 99 voltage code. The assembly is rated for -40 °C to +90 °C operation and IEC 529 IP68 dust-tight and waterproof exposure.
PIM3 -116 at 2 x 43 dBm, 1.9 GHz tonesdBc
Product family PTR replaceable gas discharge tube protector
Frequency range dc to 3.2GHz
Through current 10 max at 65 VA
Maximum transient 50kA
Nominal impedance 50ohm
Protection voltage 1000V
VSWR, dc to 2.5 GHz 1.15 max
VSWR, 2.5 to 3.0 GHz 1.20 max
VSWR, 3.0 to 3.2 GHz 1.35 typ
Connector configuration N-male to N-female
Protection voltage code 99
Dust and waterproof rating IEC 529 IP68, dust-tight and waterproof 24 h / 1 m
Multiple strike capability 20, 10 timeskA
Operating temperature range -40 to +90°C
RF power for voltage code 99 4500W
Insertion loss, dc to 2.5 GHz 0.10 maxdB
Insertion loss, 2.5 to 3.0 GHz 0.15 maxdB
Insertion loss, 3.0 to 3.2 GHz 0.25 typdB
Let-through for voltage code 99 2200 Vpk / 14 mJ

Если у вас не открывается документ, нажмите, чтобы открыть файл в новой вкладке.