The PX2DS1XX2.5GABDX pressure sensor from Honeywell features a sealed gage device with an operating pressure range of 0 to 2500kPa. It has an accuracy of ±0.25% and can withstand a maximum overload pressure of 6895kPa. The sensor operates within a temperature range of -40 to 125 degrees Celsius and can be supplied with a voltage between 13 and 30 volts. The maximum supply current is 5.5 milliamperes. The sensor is available with a 9/16-18 UNF port size and features a Deutsch electrical termination. It has an IP6K9K rating and can operate in air or liquid media, producing an output voltage of 0.25 to 10.25 volts with a response time of 2 milliseconds.
| RoHS |
Yes |
| Media |
Air|Liquid |
| Accuracy |
±0.25% |
| IP Rating |
IP6K9K |
| Pin Count |
3 |
| Port Size |
9/16-18 UNF |
| RoHS Version |
2011/65/EU |
| Response Time |
2ms |
| Output Voltage |
0.25 to 10.25V |
| Device Pressure Type |
Sealed Gage |
| Electrical Termination |
Deutsch |
| Maximum Supply Current |
5.5(Typ)mA |
| Operating Pressure Range |
0kPa to 2500kPa |
| Max Operating Temperature |
125°C |
| Maximum Overload Pressure |
6895kPa |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
30V |
| Min Operating Supply Voltage |
13V |
| Typical Operating Supply Voltage |
15|18|24V |