The Differential Pressure Sensor is a device that measures pressure differences between two ports. It operates within a pressure range of -30psi to 30psi and has an accuracy of ±0.25%. The sensor can withstand a maximum overload pressure of 60psi. It requires a supply voltage of 3.6V maximum and 3V minimum, with a typical operating voltage of 3.3V. The maximum supply current is 2.1mA. The operating temperature range is -40°C to 85°C. The sensor is available in an 8-pin DIP module package.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
2.1mA |
| Operating Pressure Range |
-30psi to 30psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
60psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |