The SSCDANN1.6BG6A3 is a gage pressure sensor from Honeywell, operating within a pressure range of 0 to 1.6 bar. It can withstand a maximum overload pressure of 4 bar and has an accuracy of ±0.25. The device requires a supply voltage between 3 and 3.6 volts, with a typical operating voltage of 3.3 volts. The maximum supply current is 2.1 mA, and the sensor has a response time of 0.46 seconds. It is designed for use in air or gas media and is suitable for operating temperatures between -40°C and 85°C.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
8 |
| Package/Case |
DIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Gage |
| Maximum Supply Current |
2.1mA |
| Operating Pressure Range |
0bar to 1.6bar |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
4bar |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |