The SSCSAND005PD3A3 differential pressure sensor from Honeywell offers ±0.25% accuracy over an operating temperature range of -40°C to 85°C. It can operate with a supply voltage as low as 3V and as high as 3.6V, with a typical operating voltage of 3.3V. The sensor can withstand a maximum overload pressure of 30psi and has a response time of 0.46 seconds. It is designed for use in air or gas media and has a maximum supply current of 2.1mA.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
4 |
| Package/Case |
SIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
2.1mA |
| Operating Pressure Range |
-5psi to 5psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
30psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |