The differential pressure sensor operates over a range of -15psi to 15psi with an accuracy of ±0.25. It can withstand a maximum overload pressure of 30psi and has a response time of 0.46. The device is powered by a supply voltage between 4.75 and 5.25V, with a typical operating voltage of 5V. It can draw a maximum supply current of 3A. The sensor is designed to operate within a temperature range of -40 to 85°C. It is suitable for use in air or gas environments.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
4 |
| Package/Case |
SIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Differential |
| Maximum Supply Current |
3mA |
| Operating Pressure Range |
-15psi to 15psi |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
30psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
5.25V |
| Min Operating Supply Voltage |
4.75V |
| Typical Operating Supply Voltage |
5V |