This gage pressure sensor from Honeywell has a maximum operating pressure range of 0.06bar and can withstand a maximum overload pressure of 0.5bar. The device operates within a temperature range of -40°C to 85°C and has a typical operating supply voltage of 3.3V. The sensor's accuracy is ±0.25% and it has a response time of 0.46ms. It requires a maximum supply current of 2.1mA and is suitable for use in air and gas media.
| RoHS |
Yes |
| Media |
Air|Gas |
| Accuracy |
±0.25% |
| Pin Count |
4 |
| Package/Case |
SIP Module |
| RoHS Version |
2011/65/EU |
| Response Time |
0.46ms |
| Device Pressure Type |
Gage |
| Maximum Supply Current |
2.1mA |
| Operating Pressure Range |
0bar to 0.06bar |
| Max Operating Temperature |
85°C |
| Maximum Overload Pressure |
0.5bar |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
3.6V |
| Min Operating Supply Voltage |
3V |
| Typical Operating Supply Voltage |
3.3V |