STD720
Дополнительная информация
| Stability | 0.020 |
| Rangeability | 100:1 |
| RoHS Version | 2002/95/EC |
| Response Time | 100ms |
| Safety Standard | ANSI/ISA 12.27.0 |
| LRL inH2O (mbar) | -400 (1000) |
| URL inH2O (mbar) | 400 (1000) |
| Protocol Standard | HART (version 7) |
| Reference Accuracy | 0.05 / 0.04 |
| Reference Turndown | 16:1 |
| Accuracy (Optional) | 0.04% of span |
| Accuracy (Standard) | 0.05% of span |
| Safety Certification | Full compliance to SIL 2/3 requirements |
| Max Span inH2O (mbar) | 400/(1000) |
| Min Span inH2O (mbar) | 4 (10) |
| Environmental Standard | ISO15156 |
| Maximum Turndown Ratio | 100:1 |
| Hazardous Location (uk) | UKEX (Flameproof, Intrinsically Safe, Increased Safety) |
| Hazardous Location (usa) | FM Approvals (Explosionproof, Intrinsically Safe, Nonincendive; Type 4X/IP66/IP67) |
| Hazardous Location (canada) | CSA (Explosion Proof, Intrinsically Safe, Nonincendive; Type 4X/IP66/IP67) |
| Hazardous Location (europe) | ATEX (Flameproof, Intrinsically Safe, Increased Safety) |
| Hazardous Location (international) | IECEx (Flameproof, Intrinsically Safe, Increased Safety) |