The U5134-000002-300BS pressure sensor from TE Connectivity operates over a pressure range of 0 to 300 bar with an accuracy of ±0.1%. It is a sealed device with a maximum overload pressure of 900 bar. The sensor has a 4-pin connection and is terminated with a Packard Metripak. It can be used with both gas and liquid media and has an operating temperature range of -40 to 125°C. The sensor's output voltage ranges from 0.5 to 4.5 volts, with a typical operating supply voltage of 5 volts.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±0.1% |
| Pin Count |
4 |
| Port Size |
1/4-19 BSPP |
| Port Type |
Male |
| RoHS Version |
2011/65/EU |
| Output Voltage |
0.5 to 4.5V |
| Device Pressure Type |
Sealed |
| Electrical Termination |
Packard Metripak |
| Operating Pressure Range |
0bar to 300bar |
| Max Operating Temperature |
125°C |
| Maximum Overload Pressure |
900bar |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
5.25V |
| Min Operating Supply Voltage |
4.75V |
| Typical Operating Supply Voltage |
5V |