The pressure sensor operates within a range of 0 to 300psi and is a gage device. It can withstand a maximum overload pressure of 900psi. The sensor's accuracy is ±0.1%. The operating temperature range is from -40 to 125 degrees Celsius. The maximum operating supply voltage is 30 volts, while the minimum is 8 volts. The sensor is designed for use with media such as gas and liquid, and it has a typical operating supply voltage of 9, 12, 15, 18, or 24 volts.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±0.1% |
| Pin Count |
3 |
| Port Size |
M14x1.5 |
| RoHS Version |
2011/65/EU |
| Output Voltage |
1 to 5V |
| Device Pressure Type |
Gage |
| Electrical Termination |
Cable |
| Operating Pressure Range |
0psi to 300psi |
| Max Operating Temperature |
125°C |
| Maximum Overload Pressure |
900psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
30V |
| Min Operating Supply Voltage |
8V |
| Typical Operating Supply Voltage |
9|12|15|18|24V |