The 0-300psi gage pressure sensor offers an operating temperature range of -40 to 125 degrees Celsius and an accuracy of ±0.1%. It has a maximum overload pressure of 900psi and a typical operating supply voltage of 12, 15, 18, or 24 volts. The sensor is designed for use in industrial environments and features a 3-pin cable termination with a 1/4-19 BSPP port size. It is suitable for measuring pressure in both gas and liquid media.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±0.1% |
| Pin Count |
3 |
| Port Size |
1/4-19 BSPP |
| Port Type |
Female |
| RoHS Version |
2011/65/EU |
| Device Pressure Type |
Gage |
| Electrical Termination |
Cable |
| Maximum Output Current |
20mA |
| Operating Pressure Range |
0psi to 300psi |
| Max Operating Temperature |
125°C |
| Maximum Overload Pressure |
900psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
30V |
| Min Operating Supply Voltage |
9V |
| Typical Operating Supply Voltage |
12|15|18|24V |