This sealed pressure sensor operates within a 0psi to 2psi pressure range with an accuracy of ±0.1%. It features a minimum operating temperature of -40°C and a maximum operating temperature of 125°C. The sensor is designed for use with a G 3/8 port and has an electrical termination of cable, with an IP67 rating for protection against solid particles and water. It can be used with various media types, including gas and liquid.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±0.1% |
| IP Rating |
IP67 |
| Port Size |
G 3/8 |
| RoHS Version |
2011/65/EU |
| Response Time |
2ms |
| Output Voltage |
0.5 to 4.5V |
| Device Pressure Type |
Sealed |
| Electrical Termination |
Cable |
| Operating Pressure Range |
0psi to 2psi |
| Max Operating Temperature |
125°C |
| Maximum Overload Pressure |
20000psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
30V |
| Min Operating Supply Voltage |
5V |
| Typical Operating Supply Voltage |
9|12|15|18|24V |