The pressure transducer operates over a range of 0 to 3000psi with an accuracy of ±0.1. It is designed for use in compound pressure applications and can withstand a maximum overload pressure of 20000psi. The device is rated for operation between -40 and 125 degrees Celsius and can be supplied with a voltage between 4.75 and 5.25 volts. The transducer has a response time of 3 and is suitable for use in gas and liquid media environments.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±0.1% |
| IP Rating |
IP67 |
| Port Size |
1/4-19 BSPP |
| RoHS Version |
2011/65/EU |
| Response Time |
3ms |
| Output Voltage |
0.5 to 4.5V |
| Device Pressure Type |
Compound |
| Electrical Termination |
Cable |
| Operating Pressure Range |
0psi to 3000psi |
| Max Operating Temperature |
125°C |
| Maximum Overload Pressure |
20000psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
5.25V |
| Min Operating Supply Voltage |
4.75V |
| Typical Operating Supply Voltage |
5V |