The U534E-000013-01KPA absolute pressure sensor from TE Connectivity operates within a pressure range of 0 to 1000psi and features an accuracy of ±0.1%. It has a port size of G 3/8 and is electrically terminated with a cable. The device is rated IP67 and can operate in both gas and liquid media. It has a response time of 3 and can be powered with a supply voltage of 1 to 5 volts, with typical operating voltages of 9, 12, 15, 18, or 24 volts. The sensor is designed for industrial use and has a maximum operating temperature of 125 degrees Celsius and a minimum operating temperature of -40 degrees Celsius.
| RoHS |
Yes |
| Media |
Gas|Liquid |
| Accuracy |
±0.1% |
| IP Rating |
IP67 |
| Port Size |
G 3/8 |
| RoHS Version |
2011/65/EU |
| Response Time |
3ms |
| Output Voltage |
1 to 5V |
| Device Pressure Type |
Absolute |
| Electrical Termination |
Cable |
| Operating Pressure Range |
0psi to 1000psi |
| Max Operating Temperature |
125°C |
| Maximum Overload Pressure |
20000psi |
| Min Operating Temperature |
-40°C |
| Max Operating Supply Voltage |
30V |
| Min Operating Supply Voltage |
8V |
| Typical Operating Supply Voltage |
9|12|15|18|24V |